{"id":991,"date":"2017-10-24T10:31:20","date_gmt":"2017-10-24T14:31:20","guid":{"rendered":"https:\/\/web.whoi.edu\/obslab\/?page_id=991"},"modified":"2021-06-24T09:23:37","modified_gmt":"2021-06-24T13:23:37","slug":"whoi-obs-at-sea-recovery-procedures","status":"publish","type":"page","link":"https:\/\/web.whoi.edu\/obslab\/laboratory\/qualityassurance\/whoi-obs-at-sea-recovery-procedures\/","title":{"rendered":"WHOI OBS At-Sea Recovery Procedures"},"content":{"rendered":"\n\n\t<h1>WHOI OBS At-Sea Recovery Procedures<\/h1>\n<h2 id=\"tablepress-9-name\" class=\"tablepress-table-name tablepress-table-name-id-9\">At-Sea Recovery Check-Sheets for WHOI Broadband OBS S01 on ENAM Experiment<\/h2>\n<span id=\"tablepress-9-description\" class=\"tablepress-table-description tablepress-table-description-id-9\">Please note: Most files will open as .pdf regardless of listed file extension.<\/span>\n\n<table id=\"tablepress-9\" class=\"tablepress tablepress-id-9\" aria-labelledby=\"tablepress-9-name\" aria-describedby=\"tablepress-9-description\">\n<thead>\n<tr class=\"row-1 odd\">\n\t<th class=\"column-1\"><\/th><th class=\"column-2\"><b>Sample File<\/b><\/th><th class=\"column-3\"><b>Explanation<\/b><\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n\t<td class=\"column-1\"><b>Spreadsheets to be Completed<\/b><\/td><td class=\"column-2\"><a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/ENAM_NSF_Clock_Checks.pdf\">ENAM_NSF_Clock_Checks.xlsx<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/ENAM_OBS_Config_working.pdf\">ENAM_OBS_Config_working.xls<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/ENAM_OBS_Location_Table.pdf\">ENAM_OBS_Location_Table.xls<\/a><\/td><td class=\"column-3\">Add end-of-experiment clock offsets<br \/>\nDouble-check S\/N of sensors, cables, recovery-aids on OBS<br \/>\nAdd date and time of OBS recovery<br \/>\n<br \/>\n<\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n\t<td class=\"column-1\"><b>Acoustics<\/b><\/td><td class=\"column-2\"><a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_c04_acoustics.pdf\">S01_c04_acoustics.pdf<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_c04-1427885660.pdf\">S01_c04-1427885660.txt<\/a><\/td><td class=\"column-3\">Scanned check-sheet for recovery acoustics<br \/>\nLog file from acoustics<br \/>\n<\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n\t<td class=\"column-1\"><b>OBS Debrief<\/b><\/td><td class=\"column-2\"><a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_c04_Debrief.pdf\">S01_c04_Debrief.pdf<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_COM11_2015-04-01.pdf\">S01_COM11_2015-04-01.txt<\/a><\/td><td class=\"column-3\">Scanned record of OBS debrief (filled out by hand)<br \/>\nObsterm log accompanying debrief\t<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n\t<td class=\"column-1\"><b>XML<\/b><\/td><td class=\"column-2\"><a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/recover_2017.pdf\">recover_2017.xml<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_xml_differences.pdf\">S01_xml_differences.pdf<\/a><\/td><td class=\"column-3\">XML file read from data-logger (should match XML from deployment)<br \/>\nDifference between the loaded XML and the Reference XML<\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n\t<td class=\"column-1\"><b>Baler Log Files<\/b><\/td><td class=\"column-2\"><a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_data_avail.pdf\">S01_data_avail.txt<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_messages.pdf\">S01_messages.txt<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_timing.pdf\">S01_timing.txt<\/a><\/td><td class=\"column-3\">Data Availability<br \/>\nData-loger messages<br \/>\nData-logger timing info. (jumps, clock-lock, etc.)<\/td>\n<\/tr>\n<tr class=\"row-7 odd\">\n\t<td class=\"column-1\"><b>Processed Guralp data from seismometer controller<\/b><br \/>\n(These files and the pdfs following are all generated from<br \/>\nraw log files recorded by the seismometer controller)<\/td><td class=\"column-2\"><a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_A047_C04_summary_pdata.pdf\">S01_A047_C04_summary_pdata.txt<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_A047_C04_summary.pdf\">S01_A047_C04_summary.csv<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_A047_C04_summary_log.pdf\">S01_A047_C04_summary_log.txt<\/a><\/td><td class=\"column-3\">Unprocessed engineering data extracted from raw log files<br \/>\nProcessed engineering data recorded in seismometer housing, ready for plotting \/ analysis<br \/>\nSummary of special events from raw log files (leveling events, centering events, low voltage detection)<\/td>\n<\/tr>\n<tr class=\"row-8 even\">\n\t<td class=\"column-1\"><b>Plots from Guralp data from seismometer controller <br \/>\n<\/b>(These pdfs are visualizations of the summary.csv above)<\/td><td class=\"column-2\"><a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_A047_C04_1.pdf\">S01_A047_C04_1.pdf<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_A047_C04_2.pdf\">S01_A047_C04_2.pdf<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_A047_C04_3.pdf\">S01_A047_C04_3.pdf<\/a><\/td><td class=\"column-3\">System voltages<br \/>\nTilt readings<br \/>\nSeismometer mass positions<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-9 from cache -->\n\n","protected":false},"excerpt":{"rendered":"<p>WHOI OBS At-Sea Recovery Procedures<\/p>\n","protected":false},"author":173,"featured_media":0,"parent":195,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/pages\/991"}],"collection":[{"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/users\/173"}],"replies":[{"embeddable":true,"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/comments?post=991"}],"version-history":[{"count":2,"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/pages\/991\/revisions"}],"predecessor-version":[{"id":1202,"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/pages\/991\/revisions\/1202"}],"up":[{"embeddable":true,"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/pages\/195"}],"wp:attachment":[{"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/media?parent=991"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}