


{"id":923,"date":"2017-10-23T14:53:57","date_gmt":"2017-10-23T18:53:57","guid":{"rendered":"https:\/\/web.whoi.edu\/obslab\/?page_id=923"},"modified":"2021-06-24T09:21:12","modified_gmt":"2021-06-24T13:21:12","slug":"whoi-obs-shoreside-procedures","status":"publish","type":"page","link":"https:\/\/web.whoi.edu\/obslab\/laboratory\/qualityassurance\/whoi-obs-shoreside-procedures\/","title":{"rendered":"WHOI OBS Shore-Side Procedures"},"content":{"rendered":"\n\n\t<h1>WHOI OBS Shore-Side Procedures<\/h1>\n<h2 id=\"tablepress-7-name\" class=\"tablepress-table-name tablepress-table-name-id-7\">Shore-Side Mobilization Check-Sheets for WHOI BB OBS S01 Prior to ENAM Experiment<\/h2>\n<span id=\"tablepress-7-description\" class=\"tablepress-table-description tablepress-table-description-id-7\">Please note: Most files will open as .pdf regardless of listed file extension.<\/span>\n\n<table id=\"tablepress-7\" class=\"tablepress tablepress-id-7\" aria-labelledby=\"tablepress-7-name\" aria-describedby=\"tablepress-7-description\">\n<thead>\n<tr class=\"row-1 odd\">\n\t<th class=\"column-1\"><\/th><th class=\"column-2\"><b>Sample File<\/b><\/th><th class=\"column-3\"><b>Explanation<\/b><\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n\t<td class=\"column-1\"><b>Check-Sheets for CableEye Tests <\/b><br \/>\n<\/td><td class=\"column-2\"><a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/AB_S01.pdf\">AB_S01.pdf<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/BB1_S01.pdf\">BB1_S01.pdf<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/BB2_S01.pdf\">BB2_S01.pdf<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/Jbox16.pdf\">Jbox16.pdf<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S1-34.pdf\">S1-34.pdf<\/a><\/td><td class=\"column-3\">Cables &amp; penetrators for glass-ball holding data logger<br \/>\nCables &amp; penetrators for battery-ball #1<br \/>\nCables &amp; penetrators for battery-ball #2<br \/>\nCables &amp; connectors for junction-box<br \/>\nCables &amp; connectors for seismometer pressure housing<br \/>\n<\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n\t<td class=\"column-1\"><b>Scanned Check-Sheets for Acquisition Ball Housing<\/b><\/td><td class=\"column-2\"><a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_KeepAlive_Test.pdf\">S01_KeepAlive_Test.pdf<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_AB_Qualification.pdf\">S01_AB_Qualification.pdf<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_AB_PreSealTest.pdf\">S01_AB_PreSealTest.pdf<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_AB_PostSealTest.pdf\">S01_AB_PostSealTest.pdf<\/a><\/td><td class=\"column-3\">Test of Seascan clock keep-alive battery<br \/>\nChecksheet for assembly of AB housing.  Typically recorded in spreadsheet now.<br \/>\nTests all functions of the AB housing prior to sealing<br \/>\nRepeat of tests but now after sealing<\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n\t<td class=\"column-1\"><b>Scanned Check-Sheets for Battery Ball Housing <\/b>(Includes assembly records and battery test sheets.  <br \/>\nBattery and release subsystems tested on these records.)<\/td><td class=\"column-2\"><a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_BB1_Assembly.pdf\">S01_BB1_Assembly.pdf<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_BB2_Assembly.pdf\">S01_BB2_Assembly.pdf<\/a><\/td><td class=\"column-3\">For Battery Ball #1<br \/>\nFor Battery Ball #2<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n\t<td class=\"column-1\"><b>Automated Battery Tester<\/b><\/td><td class=\"column-2\"><a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/Batt14_270.pdf\">Batt14_270.txt<\/a><\/td><td class=\"column-3\">One of the many text log files created by the battery tester.<\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n\t<td class=\"column-1\"><b>Storage Device (Baler) Wiping<\/b><\/td><td class=\"column-2\"><a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_Wipe.pdf\">S01_Wipe.txt<\/a><br \/>\nbaler_01027\/<\/td><td class=\"column-3\">Baler info web page, showing disk is nearly empty<br \/>\nFolder name for Baler wiping confirmation.  Folder is one of a series that sit below an experiment-specific folder.<\/td>\n<\/tr>\n<tr class=\"row-7 odd\">\n\t<td class=\"column-1\"><b>Obsterm and Baler logs from full system test<\/b> (w\/ downloaded data chunks)<\/td><td class=\"column-2\"><a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_COM8_2014-03-21.pdf\">S01_COM8_2014-03-21.txt<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_COM8_2014-03-24.pdf\">S01_COM8_2014-03-24.txt<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_Avail.pdf\">S01_Avail.txt<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_Msg.pdf\">S01_Msg.txt<\/a><br \/>\n<a href=\"https:\/\/web.whoi.edu\/obslab\/wp-content\/uploads\/sites\/98\/2017\/10\/S01_Timing.pdf\">S01_Timing.txt<\/a><\/td><td class=\"column-3\">Setting up the test<br \/>\nFinishing the test<br \/>\nBaler logs<br \/>\nBaler logs<br \/>\nBaler logs<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-7 from cache -->\n\n","protected":false},"excerpt":{"rendered":"<p>WHOI OBS Shore-Side Procedures<\/p>\n","protected":false},"author":173,"featured_media":0,"parent":195,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/pages\/923"}],"collection":[{"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/users\/173"}],"replies":[{"embeddable":true,"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/comments?post=923"}],"version-history":[{"count":3,"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/pages\/923\/revisions"}],"predecessor-version":[{"id":1200,"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/pages\/923\/revisions\/1200"}],"up":[{"embeddable":true,"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/pages\/195"}],"wp:attachment":[{"href":"https:\/\/web.whoi.edu\/obslab\/wp-json\/wp\/v2\/media?parent=923"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}